35SL
Polar Interface Homodimer - S2B
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-ID |
| Synchrotron site | APS |
| Beamline | 22-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2026-03-19 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 1.000 |
| Spacegroup name | P 32 2 1 |
| Unit cell lengths | 43.578, 43.578, 151.542 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 37.740 - 1.800 |
| R-factor | 0.1894 |
| Rwork | 0.184 |
| R-free | 0.23970 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.302 |
| Data reduction software | PROTEUM PLUS (2025.6-0) |
| Data scaling software | PROTEUM PLUS (2025.6-0) |
| Phasing software | PHASER |
| Refinement software | PHENIX (2.0_5936) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 37.740 | 1.830 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Number of reflections | 29399 | 1260 |
| <I/σ(I)> | 14.13 | |
| Completeness [%] | 98.5 | |
| Redundancy | 4.9 | |
| CC(1/2) | 0.998 | 0.528 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293.15 | 10% w/v 2-Propanol, 0.1 M Bicine, 30% w/v Polyethylene Glycol 1,500 |