Loading
PDBj
✖
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

35SL

Polar Interface Homodimer - S2B

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2026-03-19
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.000
Spacegroup nameP 32 2 1
Unit cell lengths43.578, 43.578, 151.542
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution37.740 - 1.800
R-factor0.1894
Rwork0.184
R-free0.23970
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.012
RMSD bond angle1.302
Data reduction softwarePROTEUM PLUS (2025.6-0)
Data scaling softwarePROTEUM PLUS (2025.6-0)
Phasing softwarePHASER
Refinement softwarePHENIX (2.0_5936)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]37.7401.830
High resolution limit [Å]1.8001.800
Number of reflections293991260
<I/σ(I)>14.13
Completeness [%]98.5
Redundancy4.9
CC(1/2)0.9980.528
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293.1510% w/v 2-Propanol, 0.1 M Bicine, 30% w/v Polyethylene Glycol 1,500

261139

PDB entries from 2026-10-21