2ZTC
MtRuvA Form II
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2006-11-10 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.54 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 131.200, 95.669, 77.209 |
Unit cell angles | 90.00, 121.80, 90.00 |
Refinement procedure
Resolution | 30.000 - 2.800 |
R-factor | 0.2293 |
Rwork | 0.229 |
R-free | 0.28880 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2h5x |
RMSD bond length | 0.009 |
RMSD bond angle | 1.300 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASES |
Refinement software | PHENIX |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 2.900 |
High resolution limit [Å] | 2.800 | 2.800 |
Rmerge | 0.070 | 0.472 |
Number of reflections | 19886 | |
<I/σ(I)> | 18.9 | 2.8 |
Completeness [%] | 97.3 | 95.8 |
Redundancy | 3.8 | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 297 | Crystallized using 0.1M sodium succinate, pH5.5, 1.7M ammonium sulfate as the precipitant, pH8.0, VAPOR DIFFUSION, HANGING DROP, temperature 297K |