Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2ZRG

MsRecA Q196N dATP form II'

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]296
Detector technologyIMAGE PLATE
Collection date2007-12-19
DetectorMAR scanner 345 mm plate
Wavelength(s)1.54
Spacegroup nameP 61
Unit cell lengths103.619, 103.619, 75.710
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution28.930 - 3.500
R-factor0.209
Rwork0.209
R-free0.27600
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1ubc
RMSD bond length0.009
RMSD bond angle1.800
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareAMoRE
Refinement softwareCNS (1.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0003.690
High resolution limit [Å]3.5003.500
Rmerge0.1270.494
Number of reflections5943
<I/σ(I)>9.52.2
Completeness [%]99.9100
Redundancy3.23.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.929680mM citrate/phosphate buffer(pH 6.9), 80mM NaCl, 40mM ammonium acetate, 20mM sodium citrate, 6% poly-ethylene glycol 3350, 30% poly-ethylene glycol 3350, 200mM ammonium acetate in sodium citrate buffer(PH 5.8), VAPOR DIFFUSION, HANGING DROP, temperature 296K

220113