Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

2ZGY

PARM with GDP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSPRING-8 BEAMLINE BL44B2
Synchrotron siteSPring-8
BeamlineBL44B2
Temperature [K]100
Detector technologyCCD
Collection date2006-07-18
DetectorADSC QUANTUM 210
Wavelength(s)1.0000
Spacegroup nameP 41
Unit cell lengths64.437, 64.437, 201.021
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution44.440 - 1.900
R-factor0.216
Rwork0.216
R-free0.25700
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)PDB CODE 1MWM
RMSD bond length0.013
RMSD bond angle1.800
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwareCNS (1.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.970
High resolution limit [Å]1.9001.900
Rmerge0.0510.326
Number of reflections62671
<I/σ(I)>65.522.05
Completeness [%]97.588.6
Redundancy5.73.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.229012% (W/W) PEG 8000, 0.4M SODIUM CHLORID, 0.4M MAGNESIUM ACETATE, 0.1M SODIUM CACODYLATE, pH 6.2, VAPOR DIFFUSION, HANGING DROP, temperature 290.0K

229380