2Z5K
Complex of Transportin 1 with TAP NLS
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PHOTON FACTORY BEAMLINE AR-NW12A |
| Synchrotron site | Photon Factory |
| Beamline | AR-NW12A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2007-02-11 |
| Detector | ADSC QUANTUM 210 |
| Wavelength(s) | 1.0000 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 69.643, 119.737, 147.853 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 43.400 - 2.600 |
| R-factor | 0.22291 |
| Rwork | 0.221 |
| R-free | 0.26770 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2z5o |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.186 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.700 |
| High resolution limit [Å] | 2.600 | 2.600 |
| Rmerge | 0.044 | 0.308 |
| Number of reflections | 35538 | |
| <I/σ(I)> | 13.4 | 2.6 |
| Completeness [%] | 96.3 | 87.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |