2Z5K
Complex of Transportin 1 with TAP NLS
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PHOTON FACTORY BEAMLINE AR-NW12A |
Synchrotron site | Photon Factory |
Beamline | AR-NW12A |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-02-11 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 1.0000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 69.643, 119.737, 147.853 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.400 - 2.600 |
R-factor | 0.22291 |
Rwork | 0.221 |
R-free | 0.26770 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2z5o |
RMSD bond length | 0.010 |
RMSD bond angle | 1.186 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.700 |
High resolution limit [Å] | 2.600 | 2.600 |
Rmerge | 0.044 | 0.308 |
Number of reflections | 35538 | |
<I/σ(I)> | 13.4 | 2.6 |
Completeness [%] | 96.3 | 87.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |