Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 17-ID |
| Synchrotron site | APS |
| Beamline | 17-ID |
| Detector technology | CCD |
| Collection date | 2004-11-22 |
| Detector | ADSC QUANTUM 210 |
| Wavelength(s) | 0.9792 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 42.959, 85.861, 102.558 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 65.800 - 2.100 |
| R-factor | 0.18352 |
| Rwork | 0.181 |
| R-free | 0.22255 |
| Structure solution method | SAD |
| RMSD bond length | 0.016 |
| RMSD bond angle | 1.483 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | SnB |
| Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 65.800 | 2.170 |
| High resolution limit [Å] | 2.100 | 2.100 |
| Rmerge | 0.078 | 0.269 |
| Number of reflections | 22884 | |
| <I/σ(I)> | 18.5 | 3.7 |
| Completeness [%] | 99.0 | 96.9 |
| Redundancy | 4 | 3.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 290 | 25% PEG 3350, 0.2N NaCl, 0.1M bis-Tris, pH 5.5, VAPOR DIFFUSION, SITTING DROP, temperature 290K |