2XV5
Human lamin A coil 2B fragment
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X10SA |
| Synchrotron site | SLS |
| Beamline | X10SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2007-11-17 |
| Detector | DECTRIS PILATUS 6M |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 35.093, 50.114, 89.745 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 33.000 - 2.400 |
| R-factor | 0.24523 |
| Rwork | 0.241 |
| R-free | 0.28412 |
| Structure solution method | SAD |
| Starting model (for MR) | NONE |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.149 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALEPACK |
| Phasing software | SHELXD |
| Refinement software | REFMAC (5.5.0102) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 33.000 | 2.500 |
| High resolution limit [Å] | 2.400 | 2.400 |
| Rmerge | 0.060 | 0.250 |
| Number of reflections | 5783 | |
| <I/σ(I)> | 19.9 | 3.9 |
| Completeness [%] | 97.1 | 81.2 |
| Redundancy | 9.9 | 4.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | 8.5 | 293 | 73% MPD, 10 MM TRIS-HCL, PH 8.5 AND 100 MM NACL, 293 K |