2X79
Inward facing conformation of Mhp1
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID29 |
| Synchrotron site | ESRF |
| Beamline | ID29 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2004-06-13 |
| Detector | ADSC QUANTUM 315 |
| Spacegroup name | P 61 |
| Unit cell lengths | 173.888, 173.888, 74.502 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 33.388 - 3.800 |
| R-factor | 0.2773 |
| Rwork | 0.273 |
| R-free | 0.31260 |
| Structure solution method | SAD |
| Starting model (for MR) | NONE |
| RMSD bond length | 0.115 |
| RMSD bond angle | 1.037 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | SHARP |
| Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 40.000 | 3.940 |
| High resolution limit [Å] | 3.800 | 3.800 |
| Rmerge | 0.080 | 0.690 |
| Number of reflections | 47973 | |
| <I/σ(I)> | 17.6 | 1.4 |
| Completeness [%] | 97.0 | 96 |
| Redundancy | 3.8 | 2.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | 9 | 24-28% PEG300, 100 MM NACL AND 100 MM BICINE PH9.0 |