2WTR
Full length Arrestin2
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I03 |
| Synchrotron site | Diamond |
| Beamline | I03 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2008-06-30 |
| Detector | ADSC CCD |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 62.290, 72.930, 115.360 |
| Unit cell angles | 90.00, 98.33, 90.00 |
Refinement procedure
| Resolution | 47.074 - 2.900 |
| R-factor | 0.2508 |
| Rwork | 0.248 |
| R-free | 0.29510 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1g4m |
| RMSD bond length | 0.002 |
| RMSD bond angle | 0.548 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 3.060 |
| High resolution limit [Å] | 2.900 | 2.900 |
| Rmerge | 0.080 | 0.050 |
| Number of reflections | 22285 | |
| <I/σ(I)> | 11.1 | 2.5 |
| Completeness [%] | 97.5 | 97.3 |
| Redundancy | 2.5 | 2.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 277 | CRYSTALS WERE GROWN USING THE HANGING-DROP METHOD IN A NEXTAL TRAY (QIAGEN) AT 277 K AGAINST A 1 ML RESERVOIR SOLUTION CONSISTING OF 12% (W/V) PEG 2000, 0.1M BACL2, 0.1 M TRIS-HCL PH7.5. THE HANGING DROP CONTAINED 2 MICROLITRES OF CONCENTRATED ARRESTIN2 PROTEIN (BETWEEN 9-11 MG/ML IN 0.1M TRIS-HCL PH 8.5) AND 2 MICROLITRES OF RESERVOIR SOLUTION. |