2W3C
Globular head region of the human general vesicular transport factor p115
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.2 |
Synchrotron site | BESSY |
Beamline | 14.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2008-03-12 |
Detector | MARMOSAIC 225 mm CCD |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 175.550, 68.890, 85.750 |
Unit cell angles | 90.00, 108.74, 90.00 |
Refinement procedure
Resolution | 19.850 - 2.220 |
R-factor | 0.222 |
Rwork | 0.219 |
R-free | 0.26900 |
Structure solution method | SAD |
Starting model (for MR) | NONE |
RMSD bond length | 0.012 |
RMSD bond angle | 1.450 |
Data reduction software | XDS |
Data scaling software | SCALEPACK |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.850 | 2.350 |
High resolution limit [Å] | 2.220 | 2.220 |
Rmerge | 0.070 | |
Number of reflections | 43877 | |
<I/σ(I)> | 10.2 | |
Completeness [%] | 90.5 | 82.5 |
Redundancy | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 7.5 | pH 7.5 |