2VRA
Drosophila Robo IG1-2 (monoclinic form)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SRS BEAMLINE PX10.1 |
Synchrotron site | SRS |
Beamline | PX10.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-06-21 |
Detector | MARRESEARCH |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 64.935, 84.430, 107.133 |
Unit cell angles | 90.00, 98.55, 90.00 |
Refinement procedure
Resolution | 20.000 - 3.200 |
R-factor | 0.2513 |
Rwork | 0.251 |
R-free | 0.28600 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2vr9 |
RMSD bond length | 0.009 |
RMSD bond angle | 1.400 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | CNS (1.2) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 3.370 |
High resolution limit [Å] | 3.200 | 3.200 |
Rmerge | 0.110 | 0.400 |
Number of reflections | 19035 | |
<I/σ(I)> | 9.9 | 3.1 |
Completeness [%] | 99.6 | 100 |
Redundancy | 3.7 | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |