Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2VRA

Drosophila Robo IG1-2 (monoclinic form)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSRS BEAMLINE PX10.1
Synchrotron siteSRS
BeamlinePX10.1
Temperature [K]100
Detector technologyCCD
Collection date2007-06-21
DetectorMARRESEARCH
Spacegroup nameP 1 21 1
Unit cell lengths64.935, 84.430, 107.133
Unit cell angles90.00, 98.55, 90.00
Refinement procedure
Resolution20.000 - 3.200
R-factor0.2513
Rwork0.251
R-free0.28600
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2vr9
RMSD bond length0.009
RMSD bond angle1.400
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareCNS (1.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0003.370
High resolution limit [Å]3.2003.200
Rmerge0.1100.400
Number of reflections19035
<I/σ(I)>9.93.1
Completeness [%]99.6100
Redundancy3.73.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

219869

PDB entries from 2024-05-15