2VM6
Human Bcl2-A1 in complex with Bim-BH3 peptide
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID14-1 |
| Synchrotron site | ESRF |
| Beamline | ID14-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2007-09-27 |
| Detector | ADSC CCD |
| Spacegroup name | H 3 2 |
| Unit cell lengths | 70.800, 70.800, 208.800 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 20.000 - 2.200 |
| R-factor | 0.196 |
| Rwork | 0.194 |
| R-free | 0.25000 |
| Structure solution method | MAD |
| Starting model (for MR) | NONE |
| RMSD bond length | 0.014 |
| RMSD bond angle | 1.401 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | SOLVE |
| Refinement software | REFMAC (5.3.0040) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 2.300 |
| High resolution limit [Å] | 2.200 | 2.200 |
| Rmerge | 0.066 | 0.520 |
| Number of reflections | 10576 | |
| <I/σ(I)> | 30.27 | 4.75 |
| Completeness [%] | 99.7 | 100 |
| Redundancy | 11.7 | 8.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 5.8 | 293 | 0.1M BIS, TRIS PH 5.8, 2M AMSO4 |