2VII
PspF1-275-Mg-AMP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID29 |
Synchrotron site | ESRF |
Beamline | ID29 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2006-11-23 |
Detector | ADSC CCD |
Spacegroup name | P 65 |
Unit cell lengths | 113.607, 113.607, 39.358 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 98.390 - 2.850 |
R-factor | 0.186 |
Rwork | 0.186 |
R-free | 0.24100 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2bjw |
RMSD bond length | 0.013 |
RMSD bond angle | 1.400 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 98.390 | 3.000 |
High resolution limit [Å] | 2.850 | 2.850 |
Rmerge | 0.140 | 0.360 |
Number of reflections | 6998 | |
<I/σ(I)> | 4.7 | 1.9 |
Completeness [%] | 100.0 | 100 |
Redundancy | 10.7 | 10.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 8 | 0.1M TRIS-HCL PH 8.0, 2.0M AMMONIUM FORMATE, 10% MPD |