2RAI
The PX-BAR membrane remodeling unit of Sorting Nexin 9
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.97952 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 65.632, 117.550, 145.814 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.760 - 3.200 |
R-factor | 0.2331 |
Rwork | 0.233 |
R-free | 0.30100 |
Structure solution method | SAD |
RMSD bond length | 0.010 |
RMSD bond angle | 1.200 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 19.900 |
High resolution limit [Å] | 3.200 |
Rmerge | 0.069 |
Number of reflections | 35702 |
<I/σ(I)> | 21.5 |
Completeness [%] | 99.2 |
Redundancy | 7.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | 1.3M Ammonium tartrate dibasic, 0.1M BIS-TRIS propane, pH 7.0 , VAPOR DIFFUSION, HANGING DROP, temperature 293K |