2QXV
Structural basis of EZH2 recognition by EED
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BSRF BEAMLINE 3W1A |
| Synchrotron site | BSRF |
| Beamline | 3W1A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2005-01-07 |
| Detector | MAR CCD 165 mm |
| Wavelength(s) | 1.10 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 50.110, 52.740, 127.740 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 20.000 - 1.820 |
| Rwork | 0.185 |
| R-free | 0.21800 |
| Structure solution method | MAD |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.390 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | SOLVE |
| Refinement software | CNS (1.1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 99.000 | 1.890 |
| High resolution limit [Å] | 1.820 | 1.820 |
| Number of reflections | 30809 | |
| <I/σ(I)> | 35.2 | |
| Completeness [%] | 99.0 | 98.7 |
| Redundancy | 6.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | 20% PEG MME 2000, 0.2M NaCl, 100mM HEPES, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 298.0K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | 20% PEG MME 2000, 0.2M NaCl, 100mM HEPES, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 298.0K |