2QW7
Carboxysome Subunit, CcmL
Experimental procedure
Experimental method | MAD |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.2.2 |
Synchrotron site | ALS |
Beamline | 8.2.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2006-09-14 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.97944, 0.979617, 0.975593 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 64.428, 107.444, 72.264 |
Unit cell angles | 90.00, 96.51, 90.00 |
Refinement procedure
Resolution | 19.900 - 2.400 |
R-factor | 0.243 |
Rwork | 0.240 |
R-free | 0.29600 |
Structure solution method | MAD |
RMSD bond length | 0.018 |
RMSD bond angle | 2.404 |
Refinement software | REFMAC |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 90.000 |
High resolution limit [Å] | 2.400 |
Rmerge | 0.129 |
Number of reflections | 52537 |
<I/σ(I)> | 6.4 |
Completeness [%] | 98.0 |
Redundancy | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 0.1M bis-Tris, 20% PEG3350, 0.3M NaCl, pH 6.5, vapor diffusion, hanging drop, temperature 298K |