2QU3
BACE1 with Compound 2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU FR-E+ SUPERBRIGHT |
Detector technology | CCD |
Collection date | 2005-01-01 |
Detector | BRUKER SMART 6000 |
Wavelength(s) | 1.5418 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 72.088, 103.844, 50.023 |
Unit cell angles | 90.00, 95.29, 90.00 |
Refinement procedure
Resolution | 19.950 - 2.000 |
R-factor | 0.235 |
Rwork | 0.235 |
R-free | 0.25800 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.012 |
RMSD bond angle | 2.000 |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 19.950 |
High resolution limit [Å] | 2.000 |
Number of reflections | 22290 |
Completeness [%] | 90.0 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.4 | 100 mM NaAcetate pH 5.4, 6% PEG 3350, VAPOR DIFFUSION, HANGING DROP |