2QLG
mPlum
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU |
Collection date | 2005-09-25 |
Wavelength(s) | 1.54 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 61.192, 78.276, 96.551 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 10.000 - 1.800 |
R-factor | 0.173 |
Rwork | 0.173 |
R-free | 0.24300 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1g7k |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | TNT |
Refinement software | TNT |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 10.000 |
High resolution limit [Å] | 1.800 |
Number of reflections | 43227 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 8.5 | 200mM NaCl, 100mM Tris pH8.5, 30% PEG 3400 |