Saccharomyces cerevisiae cytosolic exopolyphosphatase, phosphate complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-1
Synchrotron siteESRF
BeamlineID14-1
Temperature [K]100
Detector technologyCCD
DetectorADSC QUANTUM 4
Wavelength(s)0.93400
Spacegroup nameP 21 21 21
Unit cell lengths79.992, 83.039, 118.900
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution67.420 - 1.600
R-factor0.17216
Rwork0.171
R-free0.20139
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2qb6
RMSD bond length0.008
RMSD bond angle1.433
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareREFMAC (5.2.0005)
Refinement softwareREFMAC (5.2.0005)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]68.0001.690
High resolution limit [Å]1.6001.600
Number of reflections99085
<I/σ(I)>5.82.8
Completeness [%]94.674.9
Redundancy3.72.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.62917% PEG 4000, 150 mM (NH4)2SO4, pH 4.6, VAPOR DIFFUSION, HANGING DROP, temperature 291K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon