2PET
Lutheran glycoprotein, N-terminal domains 1 and 2.
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SRS BEAMLINE PX10.1 |
Synchrotron site | SRS |
Beamline | PX10.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2006-10-10 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.285 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 32.955, 111.062, 35.301 |
Unit cell angles | 90.00, 90.45, 90.00 |
Refinement procedure
Resolution | 55.640 - 1.700 |
R-factor | 0.17 |
Rwork | 0.168 |
R-free | 0.21000 |
Structure solution method | MIRAS |
RMSD bond length | 0.015 |
RMSD bond angle | 1.678 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MLPHARE (CCP4_5.99) |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 55.640 | 1.760 |
High resolution limit [Å] | 1.700 | 1.700 |
Rmerge | 0.059 | 0.264 |
Number of reflections | 24823 | |
<I/σ(I)> | 13.3 | 2.49 |
Completeness [%] | 89.1 | 48.3 |
Redundancy | 6.4 | 2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.4 | 291 | 12% PEG 20000, 6% heaxane-1,2-diol, 0.1M MES, pH 6.4, VAPOR DIFFUSION, HANGING DROP, temperature 291K |
1 | VAPOR DIFFUSION, HANGING DROP | 6.4 | 291 | 12% PEG 20000, 6% heaxane-1,2-diol, 0.1M MES, pH 6.4, VAPOR DIFFUSION, HANGING DROP, temperature 291K |
1 | VAPOR DIFFUSION, HANGING DROP | 6.4 | 291 | 12% PEG 20000, 6% heaxane-1,2-diol, 0.1M MES, pH 6.4, VAPOR DIFFUSION, HANGING DROP, temperature 291K |
1 | VAPOR DIFFUSION, HANGING DROP | 6.4 | 291 | 12% PEG 20000, 6% heaxane-1,2-diol, 0.1M MES, pH 6.4, VAPOR DIFFUSION, HANGING DROP, temperature 291K |