2PES
Urate Oxidase in complex with tris-dipicolinate Lutetium
Experimental procedure
| Experimental method | MAD |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE BM30A |
| Synchrotron site | ESRF |
| Beamline | BM30A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2006-03-20 |
| Detector | MAR CCD 165 mm |
| Wavelength(s) | 0.979700, 1.341332 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 79.550, 95.320, 104.330 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 15.000 - 1.600 |
| R-factor | 0.18 |
| Rwork | 0.179 |
| R-free | 0.19500 |
| Structure solution method | MAD |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.358 |
| Data scaling software | SCALA |
| Phasing software | SHARP |
| Refinement software | REFMAC |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 47.673 | 47.670 | 1.600 |
| High resolution limit [Å] | 1.518 | 4.800 | 1.520 |
| Rmerge | 0.066 | 0.011 | 0.011 |
| Total number of observations | 9077 | 22936 | |
| Number of reflections | 59288 | ||
| <I/σ(I)> | 4.7 | 17.5 | 0.4 |
| Completeness [%] | 96.6 | 78.7 | 84.6 |
| Redundancy | 6.6 | 5.6 | 3.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 293 | 5% PEG 8000, 0.1 Tris, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 293 | 5% PEG 8000, 0.1 Tris, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 293 | 5% PEG 8000, 0.1 Tris, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |