2OM5
N-Terminal Fragment of Human TAX1
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-10-27 |
Detector | MARRESEARCH |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 46.804, 106.916, 161.366 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.500 - 3.070 |
R-factor | 0.238 |
Rwork | 0.235 |
R-free | 0.27900 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.078 |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | REFMAC (5.2) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.500 | 3.260 |
High resolution limit [Å] | 3.070 | 3.070 |
Number of reflections | 7518 | |
Completeness [%] | 94.9 | 76.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 291 | PEG 20k, potassium chloride, tris, pH 8.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K |