2OB2

ppm1 in the absence of 1,8-ANS (cf 1JD)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsEMBL/DESY, HAMBURG BEAMLINE X13
Synchrotron siteEMBL/DESY, HAMBURG
BeamlineX13
Temperature [K]100
Detector technologyCCD
Collection date2005-05-05
DetectorMAR CCD 165 mm
Wavelength(s)0.81
Spacegroup nameP 65
Unit cell lengths110.620, 110.620, 161.940
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution33.060 - 1.920
R-factor0.209
Rwork0.206
R-free0.26800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1rjd
RMSD bond length0.020
RMSD bond angle1.875
Data reduction softwareMOSFLM
Data scaling softwareCCP4 ((SCALA))
Phasing softwareAMoRE
Refinement softwareREFMAC (5.2.0003)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]33.0591.967
High resolution limit [Å]1.9171.900
Number of reflections85540
Completeness [%]99.796.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.630015% PEG 8000, 0.2M ammonium sulfate, 0.1M MES, pH 5.6, VAPOR DIFFUSION, HANGING DROP, temperature 300K

219869

PDB entries from 2024-05-15