2JGS

Circular permutant of avidin

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyCCD
Collection date2006-10-05
DetectorADSC CCD
Spacegroup nameP 1 21 1
Unit cell lengths41.768, 79.309, 71.727
Unit cell angles90.00, 98.73, 90.00
Refinement procedure
Resolution70.890 - 1.900
R-factor0.206
Rwork0.203
R-free0.25100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2avi
RMSD bond length0.013
RMSD bond angle1.648
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwareREFMAC (5.3.0021)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.0002.000
High resolution limit [Å]1.9001.900
Rmerge0.0800.480
Number of reflections36425
<I/σ(I)>123
Completeness [%]99.899.9
Redundancy4.95
Crystallization Conditions
crystal IDmethodpHtemperaturedetails