Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2J60

H-ficolin complexed to D-fucose

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-1
Synchrotron siteESRF
BeamlineID14-1
Temperature [K]100
Detector technologyCCD
Collection date2005-11-17
DetectorADSC CCD
Spacegroup nameP 41 21 2
Unit cell lengths62.000, 62.000, 346.800
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution15.000 - 1.800
R-factor0.214
Rwork0.212
R-free0.25800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2j3g
RMSD bond length0.010
RMSD bond angle1.228
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareAMoRE
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 Overall
Low resolution limit [Å]46.220
High resolution limit [Å]1.800
Rmerge0.120
Number of reflections29088
<I/σ(I)>12.5
Completeness [%]99.0
Redundancy6.9