2IXL
RmlC S. suis with dTDP-rhamnose
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SRS BEAMLINE PX9.6 |
| Synchrotron site | SRS |
| Beamline | PX9.6 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Detector | ADSC CCD |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 51.408, 141.526, 53.586 |
| Unit cell angles | 90.00, 92.57, 90.00 |
Refinement procedure
| Resolution | 42.680 - 1.600 |
| R-factor | 0.169 |
| Rwork | 0.167 |
| R-free | 0.21200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.300 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 43.000 | 1.700 |
| High resolution limit [Å] | 1.600 | 1.600 |
| Rmerge | 0.070 | 0.250 |
| Number of reflections | 99569 | |
| <I/σ(I)> | 6.6 | 2.8 |
| Completeness [%] | 99.0 | 95 |
| Redundancy | 4.9 | 4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 |