Experimental procedure
Experimental method | MAD |
Source type | ROTATING ANODE |
Source details | BRUKER AXS MICROSTAR |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2003-09-15 |
Detector | BRUKER PROTEUM X8 |
Wavelength(s) | 1.54, 0.9798, 0.9795, 0.9568 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 29.070, 29.070, 184.710 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.000 - 1.470 |
R-factor | 0.137 |
Rwork | 0.139 |
R-free | 0.22600 |
Structure solution method | MAD |
RMSD bond length | 0.007 |
RMSD bond angle | 2.200 |
Data reduction software | PROTEUM PLUS |
Data scaling software | HKL-2000 |
Phasing software | SOLVE |
Refinement software | SHELXL-97 |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 1.520 |
High resolution limit [Å] | 1.470 | 1.470 |
Number of reflections | 13454 | |
Completeness [%] | 92.1 | 82.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 21% PEGmme550, 200mM Zn acetate, 0.1M MES pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |