Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2HY6

A seven-helix coiled coil

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X4C
Synchrotron siteNSLS
BeamlineX4C
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2006-02-25
DetectorMAR scanner 345 mm plate
Wavelength(s)0.9795
Spacegroup nameP 1
Unit cell lengths31.487, 35.302, 48.985
Unit cell angles86.54, 104.28, 99.95
Refinement procedure
Resolution47.500 - 1.250
R-factor0.182
Rwork0.181
R-free0.20900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2b1f
RMSD bond length0.009
RMSD bond angle1.081
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.5001.270
High resolution limit [Å]1.2501.250
Rmerge0.0460.339
Number of reflections51370
<I/σ(I)>12.22.3
Completeness [%]91.891.4
Redundancy22
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.42950.1M potassium dihydrogen phosphate, 1.4M hexanediol, pH 5.4, VAPOR DIFFUSION, HANGING DROP, temperature 295K

219869