2H8X
Xenobiotic Reductase A-oxidized
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | ENRAF-NONIUS FR571 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2004-12-12 |
| Detector | MAR scanner 345 mm plate |
| Wavelength(s) | 1.5418 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 58.060, 83.350, 156.540 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 20.000 - 1.500 |
| R-factor | 0.184 |
| Rwork | 0.182 |
| R-free | 0.19100 |
| Structure solution method | SIRAS, Molecular Replacement |
| Starting model (for MR) | 1gwj |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.270 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | SHARP |
| Refinement software | CNS (1.1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 1.600 |
| High resolution limit [Å] | 1.500 | 1.500 |
| Number of reflections | 60235 | |
| Completeness [%] | 98.5 | 92.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 290 | Ammonium sulphate, Hepes, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 290K |