2H7S
L244A mutant of Cytochrome P450cam
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.3.1 |
Synchrotron site | ALS |
Beamline | 8.3.1 |
Temperature [K] | 77 |
Detector technology | CCD |
Collection date | 2004-09-16 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 1.1159 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 57.704, 59.853, 114.124 |
Unit cell angles | 90.00, 104.69, 90.00 |
Refinement procedure
Resolution | 50.000 - 2.150 |
R-factor | 0.2354 |
Rwork | 0.235 |
R-free | 0.24890 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | PDB code 1PHC |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | CCP4 |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.230 |
High resolution limit [Å] | 2.150 | 2.150 |
Number of reflections | 33152 | |
<I/σ(I)> | 11.7 | 2.1 |
Completeness [%] | 80.4 | 87.3 |
Redundancy | 2 | 1.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.4 | 286 | 50mM Potassium phosphate pH 7.4, 250mM KCL, 50mM dithiothreitol, 36-52% ammonium sulfate., VAPOR DIFFUSION, HANGING DROP, temperature 286K |