Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2H1B

ResA E80Q

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-2
Synchrotron siteESRF
BeamlineID14-2
Temperature [K]100
Detector technologyCCD
Collection date2006-05-07
DetectorMAR CCD 165 mm
Wavelength(s)0.93400
Spacegroup nameP 1 21 1
Unit cell lengths63.969, 46.511, 95.054
Unit cell angles90.00, 105.40, 90.00
Refinement procedure
Resolution40.000 - 1.950
R-factor0.176
Rwork0.151
R-free0.20600
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1su9
RMSD bond length0.014
RMSD bond angle1.420
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]91.6702.060
High resolution limit [Å]1.9501.950
Rmerge0.0630.148
Total number of observations21977
Number of reflections39655
<I/σ(I)>9.34.5
Completeness [%]99.9100
Redundancy4.13.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.628927 - 30 % PEG 4,000, 0.1 M Sodium Citrate pH 5 - 5.8, 0.2 M Ammonium Acetate, pH 5.6, VAPOR DIFFUSION, HANGING DROP, temperature 289K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon