Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2005-12-01 |
Detector | RIGAKU RAXIS V |
Wavelength(s) | 1.5418 |
Spacegroup name | P 4 2 2 |
Unit cell lengths | 105.076, 105.076, 41.833 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 100.000 - 2.300 |
R-factor | 0.258 |
Rwork | 0.258 |
R-free | 0.28800 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1zof |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 100.000 | 2.360 |
High resolution limit [Å] | 2.300 | 2.300 |
Number of reflections | 10337 | |
Completeness [%] | 94.6 | 91.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.8 | 300 | 1.6 M AMMONIUM SULFATE, 100 HEPES, PH 6.8, 200 MM NAAC, 20 MM NABR, 5% ETHYLENE GLYCOL, , VAPOR DIFFUSION, HANGING DROP, temperature 300K |