2GYP
Diabetes mellitus due to a frustrated Schellman motif in HNF-1a
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CHESS BEAMLINE F1 |
Synchrotron site | CHESS |
Beamline | F1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2000-08-15 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 0.9480 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 29.180, 42.950, 42.370 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.000 - 1.400 |
R-factor | 0.23 |
Rwork | 0.228 |
R-free | 0.28800 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | coordinates from 1JB6 |
RMSD bond length | 0.010 |
RMSD bond angle | 2.220 |
Data reduction software | MOSFLM |
Phasing software | CNS |
Refinement software | TNT |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 20.000 |
High resolution limit [Å] | 1.400 |
Number of reflections | 10079 |
<I/σ(I)> | 6 |
Completeness [%] | 92.0 |
Redundancy | 10 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 277 | 2 mM peptide in 100 mM Bicine buffer. Reservoir solution contained 5 mM Magnesium Formate and 30% PEG400, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K |