Experimental procedure
Source type | SYNCHROTRON |
Source details | PHOTON FACTORY BEAMLINE BL-6A |
Synchrotron site | Photon Factory |
Beamline | BL-6A |
Detector technology | DIFFRACTOMETER |
Collection date | 1990-08-03 |
Detector | WEISSENBERG |
Wavelength(s) | 1.04 |
Spacegroup name | P 62 2 2 |
Unit cell lengths | 88.000, 88.000, 164.200 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 10.000 - 2.200 |
R-factor | 0.202 |
Rwork | 0.202 |
R-free | 0.26000 |
RMSD bond length | 0.014 |
RMSD bond angle | 2.918 * |
Data reduction software | WEIS |
Phasing software | X-PLOR (3.1) |
Refinement software | X-PLOR (3.1) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 77.800 |
High resolution limit [Å] | 2.200 |
Rmerge | 0.053 * |
Number of reflections | 24571 |
Completeness [%] | 77.8 * |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | unknown * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | 1 | Tris-HCl | 50 (mM) | |
2 | 1 | 1 | 5 (mM) | ||
3 | 1 | 1 | ammonium sulfate | 25 (%sat) |