Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

2BXZ

Is radiation damage dependent on the dose-rate used during macromolecular crystallography data collection

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Spacegroup nameP 21 21 21
Unit cell lengths59.418, 66.529, 152.522
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution20.000 - 1.750
R-factor0.15
Rwork0.149
R-free0.18800
Structure solution methodOTHER
RMSD bond length0.017
RMSD bond angle1.474
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Refinement softwareREFMAC (5.2.0003)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0001.840
High resolution limit [Å]1.7501.750
Rmerge0.1100.460
Number of reflections62111
<I/σ(I)>10.82.1
Completeness [%]99.699.6
Redundancy3.53.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

229380

PDB entries from 2024-12-25