2BXZ
Is radiation damage dependent on the dose-rate used during macromolecular crystallography data collection
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID29 |
Synchrotron site | ESRF |
Beamline | ID29 |
Temperature [K] | 100 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 59.418, 66.529, 152.522 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.000 - 1.750 |
R-factor | 0.15 |
Rwork | 0.149 |
R-free | 0.18800 |
Structure solution method | OTHER |
RMSD bond length | 0.017 |
RMSD bond angle | 1.474 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Refinement software | REFMAC (5.2.0003) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 1.840 |
High resolution limit [Å] | 1.750 | 1.750 |
Rmerge | 0.110 | 0.460 |
Number of reflections | 62111 | |
<I/σ(I)> | 10.8 | 2.1 |
Completeness [%] | 99.6 | 99.6 |
Redundancy | 3.5 | 3.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |