Is radiation damage dependent on the dose-rate used during macromolecular crystallography data collection

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Spacegroup nameP 21 21 21
Unit cell lengths59.418, 66.529, 152.522
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution20.000 - 1.750
R-factor0.149
Rwork0.147
R-free0.18800
Structure solution methodOTHER
RMSD bond length0.017
RMSD bond angle1.465
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Refinement softwareREFMAC (5.2.0003)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0001.840
High resolution limit [Å]1.7501.750
Rmerge0.1000.450
Number of reflections61545
<I/σ(I)>10.42.3
Completeness [%]99.699.2
Redundancy3.53.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
120% PEG 2000 MME, 0.1 M TRIS-HCL PH 8.5, 5% GLYCEROL AND 0.1 M MGCL2

220113

PDB entries from 2024-05-22