RNase before unattenuated X-RAY burn

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-4
Synchrotron siteESRF
BeamlineID14-4
Temperature [K]100
Detector technologyCCD
Collection date2004-12-18
DetectorADSC CCD
Spacegroup nameP 32 2 1
Unit cell lengths64.132, 64.132, 63.643
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution45.000 - 1.400
R-factor0.147
Rwork0.145
R-free0.17600
Structure solution methodOTHER
RMSD bond length0.017
RMSD bond angle1.655
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareSHELXD
Refinement softwareREFMAC (5.2.0005)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.490
High resolution limit [Å]1.4001.400
Rmerge0.0400.240
Number of reflections55873
<I/σ(I)>10.933.25
Completeness [%]96.890.3
Redundancy1.91.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
15.530 % PEG 5000 MME,1 M SODIUM CHLORIDE,50 MM PH 4.5 SODIUM ACETATE

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon