2AWK
GFP R96M mature chromophore
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRL BEAMLINE BL9-1 |
| Synchrotron site | SSRL |
| Beamline | BL9-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2003-03-07 |
| Detector | ADSC QUANTUM 315 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 51.235, 62.350, 71.067 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.950 - 1.150 |
| R-factor | 0.141 |
| R-free | 0.18800 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1ema |
| RMSD bond length | 0.010 |
| RMSD bond angle | 0.020 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | AMoRE |
| Refinement software | SHELXL-97 |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 1.190 |
| High resolution limit [Å] | 1.150 | 1.150 |
| Number of reflections | 74907 | |
| <I/σ(I)> | 26.06 | 2.39 |
| Completeness [%] | 91.9 | 67.1 |
| Redundancy | 2.91 | 2.95 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 295 | PEG4000, Magnesium chloride, HEPES, pH 8.00, VAPOR DIFFUSION, HANGING DROP, temperature 295K |