2AKP
Hsp90 Delta24-N210 mutant
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2002-11-01 |
Detector | MARRESEARCH |
Wavelength(s) | 1.5418 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 90.500, 52.950, 84.240 |
Unit cell angles | 90.00, 122.05, 90.00 |
Refinement procedure
Resolution | 14.970 - 1.940 |
R-factor | 0.231 |
Rwork | 0.231 |
R-free | 0.26900 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1ah6 |
RMSD bond length | 0.011 |
RMSD bond angle | 1.500 |
Data reduction software | MOSFLM |
Data scaling software | CCP4 ((SCALA)) |
Phasing software | AMoRE |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 15.000 | 2.060 |
High resolution limit [Å] | 1.940 | 1.940 |
Number of reflections | 22195 | |
Completeness [%] | 88.2 | 85.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 291 | 20% PEG8000, pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K |