2AGQ
Fidelity of Dpo4: effect of metal ions, nucleotide selection and pyrophosphorolysis
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 95 |
| Detector technology | IMAGE PLATE |
| Collection date | 2004-12-29 |
| Detector | RIGAKU RAXIS IV |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 98.101, 103.009, 52.399 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 26.790 - 2.100 |
| R-factor | 0.227 |
| Rwork | 0.227 |
| R-free | 0.25400 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1jx4 |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.200 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | CNS |
| Refinement software | CNS (1.1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.140 |
| High resolution limit [Å] | 2.100 | 2.100 |
| Rmerge | 0.060 | 0.406 |
| Number of reflections | 30510 | |
| <I/σ(I)> | 13.9 | 1.49 |
| Completeness [%] | 95.1 | 87.6 |
| Redundancy | 2.44 | 2.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | 7 | pH 7.0 |