2A7I

On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- The Optimal Data Collection Wavelength

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsELETTRA BEAMLINE 5.2R
Synchrotron siteELETTRA
Beamline5.2R
Temperature [K]100
Spacegroup nameP 41 21 2
Unit cell lengths57.310, 57.310, 148.750
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution30.000 - 1.750
R-factor0.196
Rwork0.196
R-free0.21900
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.014
RMSD bond angle1.602
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Refinement softwareREFMAC (5.2.0005)
Data quality characteristics
 Overall
Low resolution limit [Å]30.000
High resolution limit [Å]1.750
Number of reflections25377
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

237423