Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2A7C

On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- The Optimal Data Collection Wavelength

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsELETTRA BEAMLINE 5.2R
Synchrotron siteELETTRA
Beamline5.2R
Temperature [K]100
Spacegroup nameP 21 21 21
Unit cell lengths50.350, 58.020, 74.740
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.000 - 1.650
R-factor0.156
Rwork0.155
R-free0.18200
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.013
RMSD bond angle1.435
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Refinement softwareREFMAC (5.2.0005)
Data quality characteristics
 Overall
Low resolution limit [Å]40.000
High resolution limit [Å]1.650
Number of reflections26471
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon