2A7C
On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- The Optimal Data Collection Wavelength
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ELETTRA BEAMLINE 5.2R |
| Synchrotron site | ELETTRA |
| Beamline | 5.2R |
| Temperature [K] | 100 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 50.350, 58.020, 74.740 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 40.000 - 1.650 |
| R-factor | 0.156 |
| Rwork | 0.155 |
| R-free | 0.18200 |
| Structure solution method | FOURIER SYNTHESIS |
| RMSD bond length | 0.013 |
| RMSD bond angle | 1.435 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Refinement software | REFMAC (5.2.0005) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 40.000 |
| High resolution limit [Å] | 1.650 |
| Number of reflections | 26471 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 |