Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1RUY

1930 Swine H1 Hemagglutinin

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSRS BEAMLINE PX9.6
Synchrotron siteSRS
BeamlinePX9.6
Temperature [K]100
Detector technologyCCD
Collection date2003-07-01
DetectorADSC QUANTUM 4
Spacegroup nameC 1 2 1
Unit cell lengths203.106, 83.279, 178.234
Unit cell angles90.00, 106.67, 90.00
Refinement procedure
Resolution20.000 - 2.700
R-factor0.248
Rwork0.248
R-free0.26500
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1ru7
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareCNS (1.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.820
High resolution limit [Å]2.7002.700
Rmerge0.0840.324
Number of reflections73352
<I/σ(I)>7.82
Completeness [%]90.568.4
Redundancy9.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.8291Peg5K MME, TrisHCl, Sodium citrate, pH 6.8, VAPOR DIFFUSION, HANGING DROP, temperature 291K

218853

건을2024-04-24부터공개중

PDB statisticsPDBj update infoContact PDBjnumon