1KZZ
DOWNSTREAM REGULATOR TANK BINDS TO THE CD40 RECOGNITION SITE ON TRAF3
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.1 |
Synchrotron site | ALS |
Beamline | 5.0.1 |
Temperature [K] | 110 |
Detector technology | CCD |
Collection date | 2000-09-06 |
Detector | ADSC QUANTUM 4 |
Wavelength(s) | 0.9200 |
Spacegroup name | P 3 2 1 |
Unit cell lengths | 82.500, 82.500, 77.900 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 50.000 - 3.500 |
R-factor | 0.225 * |
Rwork | 0.225 |
R-free | 0.30700 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.540 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.610 |
High resolution limit [Å] | 3.500 | 3.500 |
Rmerge | 0.079 * | |
Total number of observations | 22731 * | |
Number of reflections | 4458 * | |
Completeness [%] | 99.9 * | 99.9 |
Redundancy | 5.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.7 | 298 | unpublished data * |