1ZJF
12mer-spd-P4N
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 19-ID |
| Synchrotron site | APS |
| Beamline | 19-ID |
| Temperature [K] | 200 |
| Detector technology | CCD |
| Detector | ADSC QUANTUM 4 |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 34.106, 39.262, 51.660 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 20.000 - 2.200 |
| R-factor | 0.222 |
| Rwork | 0.229 |
| R-free | 0.25600 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | AMoRE |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.280 |
| High resolution limit [Å] | 2.200 | 2.200 |
| Number of reflections | 3846 | |
| Completeness [%] | 99.3 | 98.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.3 | 298 | PEG 400, spermidine, bis tris propane, sodium chloride, P4N, pH 7.3, VAPOR DIFFUSION, HANGING DROP, temperature 298K |