1Z6Q
Glycogen phosphorylase with inhibitor in the AMP site
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU300 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 1999-02-02 |
Detector | MARRESEARCH |
Wavelength(s) | 1.5418 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 127.500, 127.500, 115.800 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.000 - 2.030 |
R-factor | 0.22 |
Rwork | 0.210 |
R-free | 0.27000 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.029 |
RMSD bond angle | 3.300 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | X-PLOR |
Refinement software | X-PLOR |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.060 |
High resolution limit [Å] | 2.030 | 2.030 |
Number of reflections | 60467 | |
Completeness [%] | 99.0 | 99 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.7 | 293 | BES, EDTA, DTT, SPERMDINE, pH 6.7, VAPOR DIFFUSION, HANGING DROP, temperature 293K |