1YV1

Fully reduced state of nigerythrin (all ferrous)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCHESS BEAMLINE F2
Synchrotron siteCHESS
BeamlineF2
Temperature [K]118
Detector technologyCCD
Collection date2004-11-18
DetectorADSC QUANTUM 4
Wavelength(s)0.98
Spacegroup nameP 21 21 21
Unit cell lengths46.773, 72.907, 118.905
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution23.720 - 1.500
R-factor0.191
Rwork0.191
R-free0.20600
Structure solution methodMAD
RMSD bond length0.006
RMSD bond angle1.100
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareSHARP
Refinement softwareCNS (1.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]23.7201.540
High resolution limit [Å]1.5001.500
Number of reflections64794
Completeness [%]98.393
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1LIQUID DIFFUSION7.32980.2 M CaCl2 20% PEG 3350, pH 7.3, LIQUID DIFFUSION, temperature 298K