1YPE
Thrombin Inhibitor Complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU300 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2004-11-27 |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.5418 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 71.100, 71.400, 72.400 |
| Unit cell angles | 90.00, 100.60, 90.00 |
Refinement procedure
| Resolution | 10.000 - 1.810 |
| R-factor | 0.173 |
| Rwork | 0.173 |
| R-free | 0.23500 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.017 |
| RMSD bond angle | 0.025 |
| Data scaling software | SCALEPACK |
| Phasing software | CNS |
| Refinement software | SHELXL-97 |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.840 |
| High resolution limit [Å] | 1.810 | 1.810 |
| Rmerge | 0.071 | 0.177 |
| Number of reflections | 30793 | |
| <I/σ(I)> | 18.4 | 8 |
| Completeness [%] | 95.8 | 93 |
| Redundancy | 2 | 2.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 277 | phasphate buffer, sodium chloride, PEG 8000, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |