1YIZ
Aedes aegypti kynurenine aminotrasferase
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X12C |
Synchrotron site | NSLS |
Beamline | X12C |
Temperature [K] | 123 |
Detector technology | DIFFRACTOMETER |
Collection date | 2004-08-07 |
Detector | SIEMENS FOUR-CIRCLE |
Wavelength(s) | 1.1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 55.288, 94.984, 167.599 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 10.000 - 1.550 |
Rwork | 0.254 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | kat pmp form |
RMSD bond length | 0.010 |
RMSD bond angle | 2.410 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | SHELXL-97 |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 10.000 | 1.610 |
High resolution limit [Å] | 1.550 | 1.550 |
Rmerge | 0.057 | |
Number of reflections | 128458 | |
Completeness [%] | 99.3 | 99.8 |
Redundancy | 7.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 277 | PEG 1000, TRIS.HCl, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |