1VSC
VCAM-1
Experimental procedure
Detector technology | AREA DETECTOR |
Collection date | 1994-04-08 |
Detector | SIEMENS |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 122.090, 48.860, 73.440 |
Unit cell angles | 90.00, 117.42, 90.00 |
Refinement procedure
Resolution | 15.000 - 1.900 |
R-factor | 0.204 |
Rwork | 0.204 |
R-free | 0.28900 |
RMSD bond length | 0.016 |
RMSD bond angle | 29.700 * |
Data reduction software | BUDDHA |
Phasing software | X-PLOR (3.1) |
Refinement software | X-PLOR (3.1) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 100.000 |
High resolution limit [Å] | 1.900 |
Rmerge | 0.059 |
Number of reflections | 25533 |
Completeness [%] | 82.9 |
Redundancy | 3.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion, hanging drop * | 7.7 * | Wang, J., (1994) Proteins: Struct.,Funct., Genet., 20, 287. * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | VCAM-D1D2 | 11 (mg/ml) | |
2 | 1 | drop | 12.5 (mM) | ||
3 | 1 | drop | 125 (mM) | ||
4 | 1 | reservoir | PEG4000 | 20 (%(w/v)) | |
5 | 1 | reservoir | 2-propanol | 10 (%(v/v)) | |
6 | 1 | reservoir | 0.1 (M) |